Cystic Fibrosis Newborn Screening in Austria Using PAP and the Numeric Product of PAP and IRT Concentrations as Second-Tier Parameters

Zeyda, Maximilian and Schanzer, Andrea and Basek, Pavel and Bauer, Vera and Eber, Ernst and Ellemunter, Helmut and Kallinger, Margit and Riedler, Josef and Thir, Christina and Wadlegger, Franz and Zacharasiewicz, Angela and Renner, Sabine (2021) Cystic Fibrosis Newborn Screening in Austria Using PAP and the Numeric Product of PAP and IRT Concentrations as Second-Tier Parameters. Diagnostics, 11 (2). p. 299. ISSN 2075-4418

[thumbnail of diagnostics-11-00299-v2.pdf] Text
diagnostics-11-00299-v2.pdf - Published Version

Download (968kB)

Abstract

In Austria, newborns have been screened for cystic fibrosis (CF) by analyzing immunoreactive trypsinogen (IRT) from dried blood spots (DBS)s for nearly 20 years. Recently, pancreatitis-associated protein (PAP) analysis was introduced as a second-tier test with the aim of reducing recalls for second DBS cards while keeping sensitivity high. For 28 months, when IRT was elevated (65–130 ng/mL), PAP was measured from the first DBS (n = 198,927) with a two-step cut-off applied. For the last 12 months of the observation period (n = 85,421), an additional IRT×PAP cut-off was introduced. If PAP or IRT×PAP were above cut-off, a second card was analyzed for IRT and in case of elevated values identified as screen-positive. Above 130 ng/mL IRT in the first DBS, newborns were classified as screen-positive. IRT analysis of first DBS resulted in 1961 (1%) tests for PAP. In the first 16 months, 26 of 93 screen-positive were confirmed to have CF. Two false-negatives have been reported (sensitivity = 92.8%). Importantly, less than 30% of families compared to the previous IRT-IRT screening scheme had to be contacted causing distress. Adding IRT×PAP caused a marginally increased number of second cards and sweat tests to be requested during this period (15 and 3, respectively) compared to the initial IRT-PAP scheme. One case of confirmed CF was found due to IRT×PAP, demonstrating an increase in sensitivity. Thus, the relatively simple and economical algorithm presented here performs effectively and may be a useful model for inclusion of CF into NBS panels or modification of existing schemes.

Item Type: Article
Subjects: STM Repository > Medical Science
Depositing User: Managing Editor
Date Deposited: 31 Jan 2023 06:32
Last Modified: 02 Mar 2024 04:33
URI: http://classical.goforpromo.com/id/eprint/2448

Actions (login required)

View Item
View Item