Comparison between OrbscanIIz, Pentacam, Ultrasound Pachymetry (Tomey SP-100) at Different Stages of Keratoconus

Pateras, E. and Koufala, Ch. (2020) Comparison between OrbscanIIz, Pentacam, Ultrasound Pachymetry (Tomey SP-100) at Different Stages of Keratoconus. Ophthalmology Research: An International Journal, 13 (2). pp. 7-33. ISSN 2321-7227

[thumbnail of 263-Article Text-526-2-10-20220913.pdf] Text
263-Article Text-526-2-10-20220913.pdf - Published Version

Download (1MB)

Abstract

Aims: To compare results of OrbscanIIz and Pentacam and Ultrasound pachymetry at different stages of keratoconus on corneal thickness.

Sample and Study Design: 94 keratoconic patients participated in the study, of which 52 were men and 42 women. Keratoconus patients were measured with OrbscanIIz, Pentacam and Ultrasound pachymetry in pre-operation examinations for corneal collagen cross-linking. The patients belong to different keratoconus stages.

Place and Duration of Study: University of West Attica Dept Biomedical Sciensce Course Optics & Optometry in collaboration with Athens “Ophthalmologico” Clinic during the period between October 2017 to January 2019.

Methodology: Corneal Pachymetry maps correlation of three types of corneal pachymeters OrbscanIIz, Pentacam and Ultrasound pachymetry (Tomey SP-100 Pachymeter). The measurements of the thinnest point of the cornea from each patient were collected at different stages of keratoconus and compared.

Results: A sample of 188 eyes were measured at different stages of keratoconus and compared for the thinnest corneal thickness with three different measurement systems, OrbscanIIz ,Pentacam and Ultrasound pachymetry. At sublinical stage Orbscan-Pentacam had Correlation coefficient r=0,7971, Orbscan-Ultrasound r=0,7483 and Pentacam-Ultrasound r=0,9442. At 1st stage Orbscan-Pentacam had Correlation coefficient r=0,8913, Orbscan-Ultrasound r=0,8151 and Pentacam-Ultrasound r=0,8151. At 2nd stage Orbscan-Pentacam had Correlation coefficient r=0,9339, Orbscan-Ultrasound r=0,8819 and Pentacam-Ultrasound r=0,9633. For 3rd stage Orbscan-Pentacam had Correlation coefficient r=0,8317, Orbscan-Ultrasound r=0,8457 and Pentacam-Ultrasound r=0,9633. For 4th stage Orbscan-Pentacam had Correlation coefficient r=-0,4655, Orbscan-Ultrasound r=0,3089 and Pentacam-Ultrasound r=0,9633. In Iatrogenic keratoectasiaafter refractive surgery Orbscan-Pentacam had Correlation coefficient r=0,9327, Orbscan-Ultrasound r=0,3089 and Pentacam-Ultrasound r=0,9859.

Conclusion: Statistical differences between OrbscanIIz, Pentacam and Ultrasound pachymetry were found for corneal thickness in all stages of keratoconus for the thinnest point measured. Orbscan-Pentacam have statistical significant differences but weak to moderate correlation. Orbscan-Ultasound have also statistical significant differences their correlation is very weak, while Pentacam-Ultrasound have statistical significant differences smaller as the previous but their correlation is very strong at all stages of keratoconus.

Item Type: Article
Subjects: STM Repository > Medical Science
Depositing User: Managing Editor
Date Deposited: 25 Feb 2023 09:04
Last Modified: 17 May 2024 09:43
URI: http://classical.goforpromo.com/id/eprint/2799

Actions (login required)

View Item
View Item